Gas Analyzers for Animals / Insects / Plants / Human / Environmental:


Q-S153 CO2 Analyzer 0-10%


Q-S153 CO2 Analyzer is a Single Channel Non-Dispersive Infrared CO2 Analyzer which measures CO2 in 0 to 5% and 0 to 10% range with 0.01% Resolution. Q-S153 replaces our S153 CO2 Analyzer. The same dependable technology has been improved, made more rugged and modular for easy fit in our Q-Box Packages.

Q-S153 CO2 Analyzer is ideal for CO2 Exchange Measurements in Larger or more Active Animals and in situations where high CO2 fluxes may occur, such as Fermentation Processes, Human Respirometry. Q-S153 may be used in a Flow-through Gas Exchange Configuration for Instantaneous and Continuous Measurements of CO2 Exchange or as part of Qubit System's Carbon Dioxide Control System for regulating pCO2 in Growth Cabinets and Rooms.

  1. Features:
  2. Switchable Ranges of 0-5% and 0-10%CO2
  3. 0.01% CO2 Resolution on Digital Display
  4. Non-dispersive Infrared Technology
  5. Modulated Infrared Light Source = No Moving Parts
  6. 0-5V Analog Output at Both Range Settings
  7. Optional Battery Pack for Field Use
  8. Compact and Portable
  1. Applications:
  2. Respirometry in Mammals
  3. Exhaled Air Analysis in Humans
  4. Compost Monitoring
  5. Monitoring of Anaerobic Metabolism in Yeast Colonies
  1. Specifications:
  2. Operating Principle: Non-dispersive Infrared
  3. Gas Sampling Mode: Flowing Gas Stream, Sealed Chamber
  4. Maximum Gas Flow Rate: 650mL/min
  5. Measurement Range (LCD Display): 0-10%
  6. Analog Output, Low Sensitivity: 0-10%
  7. Analog output, High Sensitivity: 0–5%
  8. Accuracy: ±0.3% of Full Scale
  9. Repeatability: Better than ±1%
  10. Maximum Drift (per Year): ±0.5%
  11. Response Time (@250mL/min to 95% of Final Value): 20sec
  12. Warm-up Time: 5 min.
  13. Output (Linear) for Low Sensitivity Setting: 0-5V DC for 0-10%
  14. Output (linear) for High Sensitivity Setting: 0-5V DC for 0-5%
  15. Calibration Adjustments: Zero and Span
  16. Operating Temperature Range: 0 to 50°C
  17. Storage Temperature Range: -40 to 70°C
  18. Operating Pressure Range: ±1.5% Local Mean Pressure
  19. Humidity Range: 5 to 95% RH, Non-Condensing (recommend drying gas stream)
  20. Pressure Dependence: +0.19% Reading per mm Hg
  21. Power Requirements: 12V DC via 120V AC 60Hz Adapter
  22. Current Requirements: 175mA Average, 450mA Peak
  23. Dimensions (H × W × D) (cm): 5.5 to 9.5 × 9.5 × 17
  24. Weight: 1kg
  25. Warranty: 1 Year Limited

All Specifications are subject to change without a Prior Notice

For any sort of clarifications kindly contact:
info@globesolutionz.com